291) The four-hole plating system shown below was used to repair a mandible symphysis fracture. Which type of plating system is the one represented in the drawing? Click the picture to enlarge image.
A. Dynamic compression plate system (DCP)
B. Eccentric dynamic compression plate system (EDCP)
C. Reconstruction plate
D. Titanium hollow screw reconstruction plate (THORP)
E. Fracture plate (four-hole) with lag screws
REFERENCES & ANSWER
Greenberg A. M.: Basics of AO/ASIF Principles and Stable Internal Fixation of Mandibular Fractures, Chapter 5, in Craniomaxilofacial Fractures, (Greenberg A. M., editor), Springer-Verlag, pp. 41-67
Costantino P. D.: Principles of Facial Plating Systems, Chapter 67 in Facial Plastic and Reconstructive Surgery, (Papel, editor) Thieme, Third Edition, pp. 929-944, 2009
291) B Eccentric dynamic compression plate system (EDCP)
This database contains the entire project - MCQ's in Facial Plastic & Reconstructive Surgery. Using this database you can study facial plastic by topics, e.g. blepharoplasty, scar revision, complications, etc. I hope you enjoy your stay here!. © A. Riera March,MD [2003-2022].This blog material can be used solely for nonprofit, educational purposes. The commercial use of this material, including its publication without express written consent of this site’s author is strictly prohibited.